How to Reset Your Carrier Furnace in 5 Easy Steps

Last Updated on November 1, 2022 by Jason Nguyen

If your Carrier furnace is not working, the first thing you should do is reset it. This can be done in just five easy steps! We will walk you through each one of them so that you can get your furnace up and running again in no time.

Related: 7 Worst Furnace Brands To Avoid and 5 Most Reliable Brands

How to Reset Your Carrier Furnace in 5 Easy Steps.

If your Carrier furnace is not working properly, you may need to reset it. Here are five easy steps to reset your Carrier furnace:

  1. Turn off the power to the furnace at the breaker box.
  2. Wait for five minutes and then turn the power back on.
  3. Set the thermostat to the desired temperature.
  4. Listen for the furnace to come on and feel for warm air coming from the vents.
  5. If the furnace does not come on or there is no warm air coming from the vents, check the troubleshooting guide in your Owner’s Manual.

How to reset carrier furnace lockout.

If your Carrier furnace is locked out, there are a few things you can do to reset it.

First, check to make sure that the power is turned on and that the furnace is set to the correct mode. If everything looks good there, then the next step is to check the flame sensor. This is usually located near the burner assembly.

If the flame sensor is dirty, it can cause the furnace to lock out. Clean the sensor with a cotton swab or a soft cloth.

If that doesn’t work, you may need to replace the sensor. Once you’ve done that, you should be able to reset the furnace and get it back up and running.

How to reset Carrier furnace after power outage.

If your Carrier furnace won’t restart after a power outage, you may need to reset it. Here’s how:

  1. First, check the circuit breaker or fuse box. If the circuits are still working, proceed to step two. If they’re not, that’s likely the problem and you’ll need to call an electrician.
  2. If the power is on but your furnace still won’t start, try resetting it at the circuit breaker or fuse box.
  3. If that doesn’t work, check to see if there’s a switch inside the furnace itself that needs to be turned on.
  4. Finally, if none of those solutions work, you’ll need to call a furnace repair technician.

How to reset code 33 on Carrier furnace.

If your Carrier furnace is displaying a code 33, it may be because the blower motor is not working correctly. To reset the code, first make sure that the blower motor is turned off. Then, disconnect the power to the furnace for about 30 seconds.

After the power has been disconnected, turn the blower motor back on and see if the code 33 is still displayed. If it is, you may need to replace the blower motor.

Safety First

What is safety first?

It’s a saying we’ve all heard, but what does it mean? In the context of resetting your Carrier furnace, safety first means making sure that you take all the necessary precautions to avoid injury or damage to your property.

Before beginning any work on your furnace, be sure to disconnect the power supply. This will help prevent any accidents while you’re working.

What is a flame rollout switch?

A flame rollout switch is a device that is installed in furnaces as a safety measure. If the furnace detects that the flame from the burner is not where it is supposed to be, the switch will trip and shut off the gas to the burner. This prevents dangerous situations such as a fire in the furnace.

What Causes A Flame Rollout Switch To Trip?

One possible cause for a flame rollout switch to trip is if the furnace is not getting enough airflow. This can be caused by a clogged air filter, closed vents, or something blocking the furnace’s intake.

If the switch trips, it’s important to figure out what is causing the lack of airflow and fix the problem before resetting the switch and restarting the furnace. Otherwise, the switch will likely trip again and cause the furnace to shut down.

Another possible cause for a flame rollout switch to trip is if there is a problem with the furnace’s burner assembly. This could be caused by a dirty burner or a faulty gas valve.

If the switch trips due to a problem with the burner assembly, it’s important to have a qualified technician inspect and repair the furnace before resetting the switch and restarting it.

If the flame rollout switch trips, the furnace will shut down and need to be reset. To do this, first turn off the power to the furnace at the breaker box.

Then, locate the switch (usually on the side or back of the furnace) and flip it to the “off” position. Wait a few minutes, then flip the switch back to the “on” position. Finally, turn the power back on at the breaker box and restart the furnace.

If the flame rollout switch trips frequently, it’s important to figure out the cause and fix it. Otherwise, the furnace could be damaged or even catch fire. If you’re not sure what is causing the problem, it’s best to call a qualified technician for help.

Related: 30+ Different Types Of Furnaces With Pictures (Buying Guide)

How to reset Carrier gas furnace

If your Carrier gas furnace starts acting up, one of the first things you should do is reset it. This can often fix minor issues and get your furnace back up and running smoothly. Here’s how to reset your Carrier gas furnace:

  1. Locate the red “Reset” button on the control panel of your furnace.
  2. Press and hold the “Reset” button for three to five seconds.
  3. After releasing the “Reset” button, wait a few minutes to see if your furnace starts working properly again.

How to reset Carrier electric furnace

  1. Locate the fuse box or circuit breaker panel that serves the electric furnace.
  2. Check to see if there is a blown fuse or tripped circuit breaker. If so, replace the fuse or reset the circuit breaker and try to turn on the furnace again.
  3. If the furnace still does not come on, make sure that the power switch on the furnace is in the “On” position.
  4. If the furnace still does not come on, check to see if there is a switch on the wall near the furnace that controls power to the unit. Make sure this switch is in the “On” position as well.
  5. If the furnace still does not come on, contact a qualified electrician or HVAC technician for further troubleshooting and repairs.

Related:

Does a Carrier furnace have a reset button?

Yes, Carrier furnaces have a reset button. This button is typically located near the bottom of the furnace, on the side or back. If your furnace is not working properly, hitting the reset button may help to get it up and running again.

How long does it take a carrier furnace to reset?

It usually takes a carrier furnace about 20 minutes to reset. However, if the furnace is having difficulty starting up, it may take longer. If you’re not sure how long it should take for your furnace to reset, consult your owner’s manual or contact a qualified HVAC technician.

Why is my Carrier furnace not heating?

There are several possible reasons why your Carrier furnace may not be providing heat:

-The furnace could be turned off. Check to make sure that the furnace switch is in the “on” position.

-The pilot light may have gone out. If the pilot light is extinguished, the furnace will not be able to produce heat. Try relighting the pilot light.

-The furnace could be out of fuel. If the furnace is gas-powered, check to make sure that there is enough gas in the tank. If the furnace is oil-powered, check to see if the oil tank needs to be refilled.

-There could be an issue with the furnace’s igniter. If the igniter is damaged or dirty, it may not be able to ignite the fuel, preventing the furnace from producing heat. Try cleaning or replacing the igniter.

-There could be a problem with the furnace’s blower. If the blower is not working properly, the furnace will not be able to circulate heat. Try cleaning or replacing the blower.

What are the error codes for Carrier furnace?

Some of the most common Carrier furnace error codes include:

-E1 code, which indicates a problem with the igniter

-E2 code, which indicates a problem with the flame sensor

-E3 code, which indicates a problem with the blower motor

-E4 code, which indicates a problem with the pressure switch

-E5 code, which indicates a problem with the limit switch

What does a blinking red light mean on a Carrier furnace?

It could mean that the furnace is not getting enough power, the filters need to be replaced, or there is a problem with the igniter.

If the light is blinking red, it is important to check the owner’s manual for your specific model of furnace to determine what the problem may be. In some cases, a blinking red light simply means that the furnace is in need of maintenance.

How do you manually reset a furnace?

If your furnace won’t turn on, or if it’s blowing cold air, you may need to reset it. To do so, simply follow these steps:

  1. Turn off the power to the furnace at the breaker box.
  2. Wait 60 seconds.
  3. Turn the power back on to the furnace at the breaker box.
  4. Wait 60 seconds for the furnace to reset itself.
  5. Try turning on the furnace again. If it still doesn’t work, repeat steps 1-5.

Conclusion

If you have followed the steps above and your Carrier furnace still isn’t working, you may need to contact a professional for further assistance. In many cases, a certified technician will be able to quickly diagnose and fix the problem, getting your furnace up and running again in no time.